eTRACE-30CHT constant heating tape for roof and box gutters with 30W/m; with soldered resistance wire, gutter heating, Etherma 40909
Quantity | Base price | |
---|---|---|
To 1 | €15.95 * | €15.95 * / 1 Stück |
From 2 | €15.63 * | €15.63 * / 1 Stück |
From 4 | €15.31 * | €15.31 * / 1 Stück |
From 8 | €14.99 * | €14.99 * / 1 Stück |
Prices incl. VAT plus shipping costs
Delivery time 4-6 business days
Österreich
- Article Number: TH000083
-
Manufacturer: ETHERMA
-
EAN: 9120105410472
Constant heating tape for roof and box gutters with 30W/m, prevents snow tunneling
In winter, snow and ice can often cause annoying blockages in gutters. The eTRACE-30CHT constant heating tape from Etherma helps out here. It is ideal for heating box gutters. The tape is laid flat in the gutter and effectively prevents the formation of snow tunnels. It consists of a soft-elastic, insulated tape element with a silicone coating. This heating tape complies with VDE regulations and has a soldered resistance wire. Optimum contact between the heating tape and the gutter is required for the most cost-efficient gutter heating possible. Please note that constant heating tapes should not be installed in plastic gutters and drains. The nominal temperature of the heating tape is +200 °C, the minimum installation temperature is -60 °C and the bending radius is 25 mm. The tape is CE-compliant, can be shortened every 60 cm and has a maximum heating circuit length of 58 m at a current rating of 16 A. Heating tapes are mainly used in metal box gutters, but can also be used in other rainwater gutters.
Constant heating tape for roof or box gutters eTRACE-30CHT
- Type: eTRACE-30CHT
- Prevents: tunneling of snow and ice
- Cable type: 2-core
- Max. holding temperature: 200 °C
- Heating output: 30 W/m
- Nominal voltage: 230 V
- Nominal temperature: +200 ºC
- Min. installation temperature: - 60 ºC
- Max. individual length: 58 m
- Min. bending radius: 25 mm
- Dimensions: 11 x 8 mm
- System structure: CE compliant
- Shielding: foil
Fast effect and flexible use
- Elastic: high elasticity for flexible installation
- Excellent heat transfer
- High efficiency
- Energy efficient: no high inrush current
- Individually adjustable: can be separated every 60 cm
- Simple and quick installation
- Connection: only required from one side
- Resistant: UV and ozone-resistant
- Resistant to acids and alkalis
- Rated fuse (A): 16, heating circuit lengths (m): 58
Help for planning gutter heating
- For standard gutters, a heating output of up to 30 W/m is recommended up to an altitude of 1000 m. For box gutters, the heating output per meter is calculated as follows:
- Multiply the width of the gutter (in meters) by 250 W.
- Example: For a gutter with a width of 24 cm (0.24 m), the result is: 0.24 x 250 W = 60 W.
- This corresponds to the use of two heating strips, each with 30 W/m.
- Structure (from inside to outside): 1. Cu conductor 0.75 mm² tinned 2. Silicone strand insulation 3. Silicone inner insulation 4. Soldered heating strand 5. Protective conductor braid Cu-tinned 2.5 mm² 6. Silicone sheath
- PLEASE NOTE: Constant heating bands must not be installed in plastic gutters and drains
- Use in: roof / rain / box gutters
- Dimensions and weight: 8 x 11 x 1000 mm; 0.12 kg
- Manufacturer item number: 40909
Scope of delivery: 1 x constant heating band
Data sheet:
Installation instructions (NL):
Technical Data:
- 【Heating output to prevent the formation of snow tunnels】 With a heat output of 30 W/m and a maximum heating circuit length of 58 m at a current of 16 A, the tape offers efficient heat distribution that effectively prevents the formation of snow tunnels in gutters.
- 【Nominal temperature and maximum holding temperature】 The eTRACE-30CHT heating tape is designed to operate at a peak temperature of up to 200 °C, making it ideal for demanding applications.
- 【Minimum installation temperature and bending radius】It can be installed at installation temperatures as low as -60 °C, which ensures high flexibility even in very cold weather. The minimum bending radius of 25 mm makes it easy to adapt to the shape of the gutter.
- 【Elasticity and heat transfer】The heating tape consists of a soft elastic, insulated tape element with a silicone jacket, manufactured in accordance with VDE regulations. It contains a soldered resistance wire that ensures even heat transfer. The construction is UV and ozone resistant as well as resistant to acids and alkalis.
- 【High flexibility and installation】 The tape is CE-compliant and can be cut every 60 cm, allowing precise adjustment to different lengths. Installation is straightforward as the tape only needs to be connected from one side.